WEBSITE PERUSAHAAN

CV.MITRA KIMIA HUSADA

PT.FARMA KIMIA HUSADA

PT.DIAGNOSA LABORATORIA PERSADA

PUSAT DISTRIBUTOR IMPORTIR ALAT ALAT LABORATORIUM KIMIA FARMASI KESEHATAN REAGEN KIMIA ALAT PERAGA FISIKA KIMIA GLASSWARE

PHANTOM MANIKIN TRAINING SERVIS DAN MAINTENANCE

PERUSAHAAN DISTRIBUTOR ALAT LABORATORIUM DAN ALAT KESEHATAN

1
Rp27.000.000

Cart

PERUSAHAAN DISTRIBUTOR ALAT LABORATORIUM DAN ALAT KESEHATAN

1
Rp27.000.000

Cart

Environmental test chambers CTC / TTC CTC256

Temperature

Setting accuracy temperatureup to 99.9 °C: 0.1 / from 100 °C: 0.5
Temperature rangewithout humidity: from -42°C up to +190°C
Temperature rangewith humidity from +10°C up to +95°C
Temperature distribution (spatial)+/- 0.5 up to 2K
Temperature sensor2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error
Displayresolution of display for setpoint values 0.1°C up to 99.9°C, 0.5°C from 100°C and for actual values 0.1°C (LED)

Humidity

Humidity controlactive humidifying and de-humidifying adjustable from 10-98 % rh with digital display of relative humidity – resolution of display 0.5 %, setting accuracy 1 %
HumidificationBy hot steam generator. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7) from 2 x 10 l tank on telescopic slide integrated in chamber, with automatic change-over.

Control technology

ControllerElectronic microprocessor temperature controller with auto-diagnostic system
Set-up Displaydigital display of all set parameters, such as temperature, weekdays, time, humidity, fan speed, programme status and set-up values – language to be chosen via set-up
Timerintegrated timer for tempering profiles of up to 40 ramps each, each segment adjustable from 1 min. to 999 hrs.
Calibrationthree freely selectable temperature values, humidity 2-point calibration at 20% and 90 % rh

Ventilation

Fanhigh-performance air fan in working chamber
Fan controldepending on operation status automatic adaption of fan speed resp. manual adjustment from 10 to 100 %

Communication

Interface USBUSB-interface incl. Memmert software “Celsius” for programming and documentation
Interface Printerparallel printer interface (incl. real time clock with date function) for all PCL3-compatible ink jet printers for GLP-conforming documentation
Documentationintegrated ring memory as data logger for GLP-conforming long-term documentation of all relevant parameters – 1024 kB
Documentationprogramme stored in case of power failure
Programmingchip-card control incl. 1 MEMoryCard XL with 32 kB storage capacity (max. 40 ramps)

Safety

Temperature controlmechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature
Temperature controlover- and undertemperature monitor TWW, protection class 3.3
AutoSAFETYadditionally integrated over- and undertemperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature, compressor in case of undertemperature
Autodiagnostic systemintegral fault diagnostics for temperature and humidity control
Alarmwith visual and acoustic alarm in case of over-/under temperature and underhumidity, open door and empty water tank

Heating concept

Doordoor heating to avoid condensation
Ring heaterhigh-performance ring heaters with optimised air circulation
Coolingtwin compressor; refrigerant R449A

Standard equipment

Works calibration certificatestandard values -20 °C and +160 °C, +30 °C at 60 % rh
Doorfully insulated stainless steel door with double-locking and 4-point adjustment, heated
Entry portEntry port right, 80 mm, with stopper
Internals1 stainless steel grid(s), electropolished
InteriorEasy-to-clean stainless steel interior, materil 1.4301 (ASTM 304), hermetically welded

Stainless steel interior

Volume256 l
Dimensionsw(A) x h(B) x d(C): 640 x 670 x 597 mm
Max. number of internals6
Max. loading per internal25 kg

Textured stainless steel casing

Dimensionsw(D) x h(E) x d(F): 898 x 1730 x 1100 mm (d +50mm door handle)
Installationon lockable castors
Housingrear zinc-plated steel

Electrical data

Electrical load400 V, 3ph. w/o N 16A, 50 Hz / approx. 7000 W

Ambient conditions

Set UpThe distance between the test chamber and the walls/ceiling must be at least 25 cm.
Ambient temperature16 ºC to 28 ºC
Humidity rhmax. 70 %, non-condensing
Altitude of installationmax. 2,000 m above sea level
Pollution degree2

Packing/shipping data

Transport informationThe appliances must be transported upright
Customs tariff number8419 8998
Country of originFederal Republic of Germany
Dimensions approx incl. cartonw x h x d: 1020 x 1910 x 1310 mm
Net weightapprox. 337 kg
Gross weight cartonapprox. 463 kg

CTC256

Standard delivery Environmental test chambers

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “Environmental test chambers CTC / TTC CTC256”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

1
Rp27.000.000

Cart