Constant climate chamber HPP1400eco Memmert

Temperature

Setting temperature rangewithout light, with humidity: +15 to +60 °C
Setting temperature rangewithout light, without humidity: 0 to +70 °C
Working temperature rangewithout light, with humidity: +15 (at least 10 below ambient temperature) to +60 °C
Working temperature rangewithout light, without humidity: 0 (at least 20 below ambient temperature) to +70 °C
Setting accuracy temperature0.1 °C
Temperature sensor2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Humidity

Setting range humidity10 – 80 % rh
Humidityhumidity supply with distilled water from external tank by self-priming pump
Humidificationhumidification by hot steam generator
Dehumidificationdehumidification by cold trap using the Peltier technology
Setting accuracy humidity0.5 % rh

Control technology

ControlCOCKPITTwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Language settingGerman, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
adjustable parameterstemperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime
TimerDigital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function HeatBALANCEadapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 %
Function SetpointWAITthe process time does not start until the set temperature is reached
Calibrationthree freely selectable values each, temperature and humidity

Communication

InterfaceEthernet LAN, USB
Documentationprogramme stored in case of power failure
ProgrammingAtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

Temperature controlover- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display
AutoSAFETYadditionally integrated over- and undertemperature protection “ASF”, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature
Autodiagnostic systemintegral fault diagnostics for temperature and humidity control
Alarmvisual and acoustic

Heating concept

Peltierenergy-saving Peltier heating-/cooling system integrated in the rear (heat pump principle)

Standard equipment

Standard works calibration certificate+25 °C / 60 % rh, +40 °C / 75 % rh, 5 % CO2 at +40 °C / 75 %rh
DoorStainless steel doors with glass sectors, fully heated inner glass panes integrated in the full-sight glass door with 2-point locking (compression door lock)
Internals4 stainless steel grid(s), electropolished
Standard accessoriesWater tank including connection hose

Stainless steel interior

Dimensionsw(A) x h(B) x d(C): 1250 x 1450 x 750 mm (d less 32 mm for fan – Peltier)
Volume1360 l
Max. number of internals28
Max. loading of chamber250 kg
Max. loading per internal30 kg

Textured stainless steel casing

Dimensionsw(D) x h(E) x d(F): 1435 x 1913 x 905 mm (d +56mm door handle & +111mm Peltier element)
Installationon lockable castors, adjustable in height
Housingrear zinc-plated steel

Electrical data

Voltage Electrical load230 V, 50/60 Hz
approx. 1400 W
Voltage Electrical load115 V, 50/60 Hz
approx. 1400 W

Ambient conditions

Set UpThe distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Ambient temperature16 ºC to 40 ºC
Humidity rhmax. 70 %, non-condensing
Altitude of installationmax. 2,000 m above sea level
Overvoltage categoryII
Pollution degree2

Packing/shipping data

Transport informationThe appliances must be transported upright
Customs tariff number8419 8998
Country of originFederal Republic of Germany
WEEE-Reg.-No.DE 66812464
Dimensions approx incl. wooden boxw x h x d: 1560 x 2200 x 1190 mm
Net weightapprox. 347 kg
Gross weight wooden boxapprox. 525 kg

HPP1400eco

Standard delivery Constant climate chamber

On this page, you can find all the essential technical data on the Memmert stability chamber HPP. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “Constant climate chamber HPP1400eco Memmert”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

2
Rp57.000.000

Cart