BOD Sensor BOD Analysis
TECHNICAL DATA
| Number of sensors including: | BOD Sensor 1 BOD Sensor Set 1 BOD Sensor System 6 6 BOD Sensor System 10 10 |
| Sensor display: | 4-digit LED display |
| Bod measurement: | mg/l (ppm) directly on the display |
| Test typology: | BOD |
| BOD scales: | 90, 250, 600, 999, 4000 ppm, Higher values after dilution |
| Bottle volumes: | 500 ml |
| Data storage: | BOD values at 24h intervals |
| Sensor construction material: | Technopolymer |
| Power: | BOD Sensor – BOD Sensor Set – BOD Sensor System 6 2 W BOD Sensor System 10 2 W |
| Sensor battery type: | CR 2430 |
| Power supply: | BOD Sensor 2x3V lithium batteries BOD Sensor Set 2x3V lithium batteries BOD Sensor System 6 Sensors: 2x3V lithium batteries Stirring Station: 230V / 50-60Hz or 115V / 60Hz BOD Sensor System 10 Sensors: 2x3V lithium batteries Stirring Station: 230V / 50-60Hz or 115V / 60Hz |
| Dimensions (WxHxD): | BOD Sensor 55x71x73 mm (2.1×2.8×2.9 in) BOD Sensor Set 75x230x75 mm (3.0×9.3×3.0 in) BOD Sensor System 6 270x300x185 mm (10.6×11.8×7.3 in) BOD Sensor System 10 432x300x165 mm (17.0×11.8×6.5 in) |
| Weight: | BOD Sensor 0,08 kg (0.2 lb) BOD Sensor Set 0,4 kg (0.9 lb) BOD Sensor System 6 2,3 Kg (5.1 lb) BOD Sensor System 10 3 Kg (6.6 lb) |
| Safety class: | IEC/EN61010-1 |
| Sensor protection degree: | IP 54-EN 60529 |
| Official references | ISO 5815-1:2019 STANDARD METHOD 5210D |
Innovative, mercury-free and extremely reliable solution for BOD analysis (Biochemical Oxygen Demand).
BOD Determination made easy
BOD (Biochemical Oxygen Demand) Determination is a simple and easy way for monitoring the microorganisms’ activity in water samples with extremely reliable results.
In particular, microorganisms present or inoculated in a water sample containing biodegradable organic substance, consume oxygen for their metabolic activity and produce a corresponding volume of carbon dioxide.
The carbon dioxide get absorbed by a strong alkali positioned in the neck of the bottle. The result of this process is a decrease in gas pressure. The BOD measure this change in gas pressure between the beginning to the end of the analysis and give a result expressed in mg/l .
Safe and Easy to use
- Measurement on scales of 90, 250, 600, 999 and 4000 ppm BOD
- Higher values can be measured by diluting the sample
- Fits directly on the bottle containing the sample
- Automatically stores 5 BOD values at 24-hour intervals
- Enables analysis to continue over the weekend
- Results directly readable at any time, even after five days
- Direct readout in mg/l (ppm)
- Compact stirring stations
- Models with stirring stations offer VELP stirring quality
- IP 54 protection against particle and liquid ingress
- Class 3 IEC 1010 conformity